Heating and installation: connection diagrams for pellet boilers

Communal Pellet Boiler House With Climate Control With Apartment Weather Regulators

Heating and installation: optimal connection diagrams for FOCUS pellet boilers

How to make heating and installation of a system based on a pellet boiler? As a rule, this is the first question that arises among buyers of FOCUS heating equipment. Our company offers sets of hydraulic units based on Victaulic fittings. It is based on groovelock connections and installation without welding. The connection principle is quite simple. Any pellet boiler FOCUS you can connect to the heating system using our hydraulic piping kits. We have provided connection diagrams for additional heating equipment more than once. Optimal connection schemes collected in a separate publication. Choose the right one and do the installation.

 

For residential buildings and offices: connection diagrams for pellet boilers

In addition to industries that can scale heating capacity up to 2.5 MW, and in the case of large-scale construction, up to 2000 MW, FOCUS pellet boilers are extremely beneficial for heating private homes, offices and objects remote from infrastructure. Thanks to complete autonomy, inexpensive and renewable fuel, pellet technology is most advantageous within the OFFGRID concept. In other words, any object becomes autonomous thanks to comfortable automatic heating at the gas level.

Connection options for a pellet boiler depend on which heating circuits you want to use. In other words, if you need hot water supply, then there must be a buffer tank or indirect heating buffer in the system. These tasks are solved simultaneously in heat accumulators. 

Please note that pellet boilers regulate their operating power well using a microcontroller and sensors. But if you want to use warm floors, that is, low-temperature heating, then you will need a mixing unit. It can be implemented with a three-way valve and mix cold water in the circuit or connected to a buffer tank with heat exchangers indirect heating.

In the end, everything will depend on the price of your ideas for heating the room, which can be implemented in different ways. Options for hydraulic piping, aka optimal connection diagrams for pellet boilers, shown in the illustrations.

 

Pellet boiler room for an apartment building

As a rule, a communal boiler house will require several pellet boilers connected in cascade. For these purposes, a cascade connection scheme for heating equipment for heat supply and hot water supply is used. The task of such a system is to supply coolant and water of the same temperature to the apartment risers.

Climate Control With Unified Weather Regulator for Pellet Boilers
Pellet boiler room with climate control with a single weather regulator for pellet boilers and touch panels in apartments with thermostats on radiators

 

Pellet boiler room for greenhouses and industries

Optimal connection diagrams for pellet boilers for greenhouses and industries require the presence of high- and low-temperature heating circuits: radiator and air heating, as well as heated floors. You will also need a power supply. For these purposes it is recommended steam generators FOCUS with the following connection diagram. 

If you want to implement the system in a traditional way, we recommend cascade connection of boilers.

 

Heating And Installation: Connection Diagrams for Pellet Boilers - Firebox - Solid Fuel Pellet Boilers, Pellet Burners, Industrial
HVAC for heated greenhouses

Leave a Reply

Your email address will not be published. Required fields are marked *

en_GBEnglish (UK)
This site uses cookies to improve your browsing experience. By browsing this site you agree to our use of cookies.