Multi-circuit heating system of a private house

Multi-circuit heating system for a private house using pellets

Autonomous multi-circuit heating system of a private house and heat without gas

Comfortable modern heating based on underfloor heating, radiators, combined with hot water without gas, seems to be an unattainable luxury. Meanwhile, the FOCUS pellet boiler in monoblock format can provide this autonomously and on a cheaper fuel than gas, in combination with the climate control function. The manufacturer provides engineering services and advice on installing the boiler so that the multi-circuit heating system of a private house works without failures.

At the same time, you do not need a heating project agreed with any enterprise, which costs fabulous money for a Ukrainian with an average income. It is carried out according to heat engineering calculations and requirements by TM FOCUS dealers.

Multi-circuit heating system of a private house on pellets. Double-circuit - the most popular option for heating a private house

The most popular among consumers is the dual-circuit heating system, which serves radiators and underfloor heating. This is a budget, but comfortable heating option, which can be complicated without restrictions, thereby improving both the level of comfort and economy. What does a separate heating circuit give? First of all, the fact that it is possible to individually adjust the temperature of the water supply.

The popular format "warm floors + radiators" implies low-temperature and high-temperature heating. In the recommended pellet boiler FOCUS monoblock - this is implemented in two ways.

The budget option involves connecting the heating circuits of underfloor heating and radiators directly to the outlet of the boiler coolant. In this case, it will work either for heating underfloor heating, or for heating radiators. In other words, in summer and autumn, heating can be turned on with underfloor heating, in winter - with radiators.

This option requires minimal installation of equipment, and the coolant is supplied to the circuit using a circuit switch valve. The temperature will be regulated by mixing cold water with the help of a four-way valve, which is included in the delivery of the FOCUS monoblock pellet boiler. It is also necessary to switch the mode of using the boiler on the touch panel, all settings will be set automatically.

If you want to use both underfloor heating and radiators to heat your home at the same time, we recommend connecting an indirect heating boiler or heat accumulator through the DHW inputs, and the necessary heating circuits to this equipment. In this case, it is possible to maintain the multi-circuit heating system of a private house and regulate their temperature using analog wiring.

 

Options that are included in the delivery of the pellet boiler FOCUS monoblock

When installing the recommended equipment, it is important to take into account its features, avoiding unnecessary expenses for installation. This boiler is designed to meet most of the needs of consumers who have a single heating circuit in private houses. As options, it is proposed to use the FOCUS monoblock pellet boiler in addition to heating circuits and for hot water supply, with its help it is also possible to implement a multi-circuit heating system of a private house.

Due to the choice of some of the most common heating formats in private homes, the FOCUS pellet boiler has the following characteristics:

  • first of all, it is a single-circuit boiler with a built-in weather regulator;
  • has outlets for DHW, DHW sensor;
  • the boiler regulates the heating system pump and the DHW pump;
  • thanks to the built-in thermostat, the pellet boiler can work with underfloor heating, air heating and radiators;
  • boiler settings allow you to set modes with all options;
  • when using room thermostats, the boiler will regulate the temperature based on the temperature outside and in the room.

To this you can add options for all FOCUS boilers. This is an advanced hybrid heat exchanger with complete afterburning of condensate gases and heat extraction into the system. As a result, warm air without condensate impurities is emitted into the atmosphere. This feature allows the use of monoblock and high-ash pellets in FOCUS pellet boilers.

Leave a Reply